Re: [PATCH] Reuse Workers and Replication Slots during Logical Replication

Поиск
Список
Период
Сортировка
От Peter Smith
Тема Re: [PATCH] Reuse Workers and Replication Slots during Logical Replication
Дата
Msg-id CAHut+PtiAtGJC52SGNdobOah5ctYDDhWWKd=uP=rkRgXzg5rdg@mail.gmail.com
обсуждение исходный текст
Ответ на Re: [PATCH] Reuse Workers and Replication Slots during Logical Replication  (Melih Mutlu <m.melihmutlu@gmail.com>)
Ответы Re: [PATCH] Reuse Workers and Replication Slots during Logical Replication  (Amit Kapila <amit.kapila16@gmail.com>)
Список pgsql-hackers
On Tue, Jul 18, 2023 at 1:54 AM Melih Mutlu <m.melihmutlu@gmail.com> wrote:
>
> Hi,
>
> PFA updated patches. Rebased 0003 with minor changes. Addressed Peter's reviews for 0001 and 0002 with some small
commentsbelow. 
>
> Peter Smith <smithpb2250@gmail.com>, 10 Tem 2023 Pzt, 10:09 tarihinde şunu yazdı:
>>
>> 6. LogicalRepApplyLoop
>>
>> + /*
>> + * apply_dispatch() may have gone into apply_handle_commit()
>> + * which can call process_syncing_tables_for_sync.
>> + *
>> + * process_syncing_tables_for_sync decides whether the sync of
>> + * the current table is completed. If it is completed,
>> + * streaming must be already ended. So, we can break the loop.
>> + */
>> + if (MyLogicalRepWorker->is_sync_completed)
>> + {
>> + endofstream = true;
>> + break;
>> + }
>> +
>>
>> and
>>
>> + /*
>> + * If is_sync_completed is true, this means that the tablesync
>> + * worker is done with synchronization. Streaming has already been
>> + * ended by process_syncing_tables_for_sync. We should move to the
>> + * next table if needed, or exit.
>> + */
>> + if (MyLogicalRepWorker->is_sync_completed)
>> + endofstream = true;
>>
>> ~
>>
>> Instead of those code fragments above assigning 'endofstream' as a
>> side-effect, would it be the same (but tidier) to just modify the
>> other "breaking" condition below:
>>
>> BEFORE:
>> /* Check if we need to exit the streaming loop. */
>> if (endofstream)
>> break;
>>
>> AFTER:
>> /* Check if we need to exit the streaming loop. */
>> if (endofstream || MyLogicalRepWorker->is_sync_completed)
>> break;
>
>
> First place you mentioned also breaks the infinite loop. Such an if statement is needed there with or without
endofstreamassignment. 
>
> I think if there is a flag to break a loop, using that flag to indicate that we should exit the loop seems more
appropriateto me. I see that it would be a bit tidier without endofstream = true lines, but I feel like it would also
beless readable. 
>
> I don't have a strong opinion though. I'm just keeping them as they are for now, but I can change them if you
disagree.
>

I felt it was slightly sneaky to re-use the existing variable as a
convenient way to do what you want. But, I don’t feel strongly enough
on this point to debate it -- maybe see later if others have an
opinion about this.

>>
>>
>> 10b.
>> All the other tablesync-related fields of this struct are named as
>> relXXX, so I wonder if is better for this to follow the same pattern.
>> e.g. 'relsync_completed'
>
>
> Aren't those start with rel because they're related to the relation that the tablesync worker is syncing?
is_sync_completedis not a relation specific field. I'm okay with changing the name but feel like relsync_completed
wouldbe misleading. 

My reading of the code is slightly different: Only these fields have
the prefix ‘rel’ and they are all grouped under the comment “/* Used
for initial table synchronization. */” because AFAIK only these fields
are TWS specific (not used for other kinds of workers).

Since this new flag field is also TWS-specific, therefore IMO it
should follow the same consistent name pattern. But, if you are
unconvinced, maybe see later if others have an opinion about it.

------
Kind Regards,
Peter Smith.
Fujitsu Australia



В списке pgsql-hackers по дате отправления:

Предыдущее
От: Masahiro Ikeda
Дата:
Сообщение: Support worker_spi to execute the function dynamically.
Следующее
От: Peter Smith
Дата:
Сообщение: Re: [PATCH] Reuse Workers and Replication Slots during Logical Replication