Tom Lane napsal(a):
> Alvaro Herrera <alvherre@commandprompt.com> writes:
>> Neil Conway wrote:
>>> Sure -- I sent in a patch earlier, but I'll post an updated version
>>> shortly.
>
>> Hmm, I mean just switching the default value in configure.in ... is
>> there anything else that needs doing at this point?
>
> Well, that's hardly a one-liner. If nothing else there are probably
> multiple places in the documentation that need adjustment.
>
Does we keep same OID for this type? I prefer to redefine it as new type. It
helps to determine which type is it for upgrade purpose. I think best solution
is to have both code floating/int active and configure or initdb only perform
correct linking in BKI file to preferred variant.
The result will be two datatypes datetime and timestamp_int or timestamp_float.
Or maybe better is to have two datatypes timestamp_int timestamp_float and one
domain timestamp which points to preferred type.
Zdenek