| От | Tom Lane |
|---|---|
| Тема | Re: Autovacuum stopped running |
| Дата | |
| Msg-id | 11024.1272755375@sss.pgh.pa.us обсуждение |
| Ответ на | Re: Autovacuum stopped running ("Benjamin Krajmalnik" <kraj@illumen.com>) |
| Ответы |
Re: Autovacuum stopped running
|
| Список | pgsql-admin |
"Benjamin Krajmalnik" <kraj@illumen.com> writes:
> TO be truthful, I did not check that.
> I arrived at the conclusion because although I have 10 autovacuum
> threads, none of the tables had been autoanalyzed or autovacuumed in
> hours (and due to the nature of the activity they do so every minute).
> If I ever see this behavior now I know what to check for :) Thx.
We've seen one or two previous reports that suggested that the autovac
launcher might have stopped launching workers, but it hasn't been
reproducible. Are you using any nonstandard parameters for autovacuum?
regards, tom lane
В списке pgsql-admin по дате отправления:
Сайт использует файлы cookie для корректной работы и повышения удобства. Нажимая кнопку «Принять» или продолжая пользоваться сайтом, вы соглашаетесь на их использование в соответствии с Политикой в отношении обработки cookie ООО «ППГ», в том числе на передачу данных из файлов cookie сторонним статистическим и рекламным службам. Вы можете управлять настройками cookie через параметры вашего браузера