Re: Log-Shipping Standby Server: USE_FLOAT8_BYVAL compatibility error
| От | Mathias Breuninger |
|---|---|
| Тема | Re: Log-Shipping Standby Server: USE_FLOAT8_BYVAL compatibility error |
| Дата | |
| Msg-id | 004701cd8b47$d6a4b5f0$83ee21d0$@breuninger@espace29.asso.fr обсуждение |
| Ответ на | Re: Log-Shipping Standby Server: USE_FLOAT8_BYVAL compatibility error (Craig Ringer <ringerc@ringerc.id.au>) |
| Список | pgsql-admin |
On 09/04/2012 11:45 PM CEST, Craig Ringer wrote: > > The 64 bits server is the master and I tried to configure the 32 bits > one as a standby server. > > That isn't a supported configuration. The standby needs to be the same > architecture as the master and needs to use the same compilation > options. > > I'm surprised the error message wasn't more useful in this case. > > > I can recompile PostgreSQL on the 64bit architecture without this > configure option, but I wonder if there will be a performance drawback. > > It still won't work. If you want to replicate from a 64-bit machine to > a 32-bit machine you will need to build a 32-bit version of PostgreSQL > on the 64-bit machine. > > -- > Craig Ringer Thank you for your answers. I wasn't aware of the binary problem with replication. Maybe the PostgreSQL docs should emphasize the architecture restriction. I'll explore the other solutions. -- Mathias