Re: setting up raid10 with more than 4 drives

Поиск
Список
Период
Сортировка
От PFC
Тема Re: setting up raid10 with more than 4 drives
Дата
Msg-id op.ts5b3kikcigqcu@apollo13
обсуждение исходный текст
Ответ на Re: setting up raid10 with more than 4 drives  ("Luke Lonergan" <LLonergan@greenplum.com>)
Ответы Autodetect of software RAID1+0 fails
Список pgsql-performance
On Wed, 30 May 2007 16:36:48 +0200, Luke Lonergan
<LLonergan@greenplum.com> wrote:

>> I don't see how that's better at all; in fact, it reduces to
>> exactly the same problem: given two pieces of data which
>> disagree, which is right?
>
> The one that matches the checksum.

    - postgres tells OS "write this block"
    - OS sends block to drives A and B
    - drive A happens to be lucky and seeks faster, writes data
    - student intern carrying pizzas for senior IT staff trips over power
cord*
    - boom
    - drive B still has old block

    Both blocks have correct checksum, so only a version counter/timestamp
could tell.
    Fortunately if fsync() is honored correctly (did you check ?) postgres
will zap such errors in recovery.

    Smart RAID1 or 0+1 controllers (including software RAID) will distribute
random reads to both disks (but not writes obviously).

    * = this happened at my old job, yes they had a very frightening server
room, or more precisely "cave" ; I never went there, I didn't want to be
the one fired for tripping over the wire...


    From Linux Software RAID howto :

    - benchmarking (quite brief !)
    http://unthought.net/Software-RAID.HOWTO/Software-RAID.HOWTO-9.html#ss9.5

    - read "Data Scrubbing" here :
http://gentoo-wiki.com/HOWTO_Install_on_Software_RAID

    - yeah but does it work ? (scary)
http://bugs.donarmstrong.com/cgi-bin/bugreport.cgi?bug=405919

  md/sync_action
       This can be used to monitor and control the resync/recovery
       process of MD. In particular, writing "check" here will cause
       the array to read all data block and check that they are
       consistent (e.g. parity is correct, or all mirror replicas are
       the same). Any discrepancies found are NOT corrected.

       A count of problems found will be stored in md/mismatch_count.

       Alternately, "repair" can be written which will cause the same
       check to be performed, but any errors will be corrected.