Re: Pasword expiration warning

Поиск
Список
Период
Сортировка
От Gilles Darold
Тема Re: Pasword expiration warning
Дата
Msg-id b1d584c7-5e5b-4bc7-8e8c-92a3a2c19322@darold.net
обсуждение исходный текст
Ответ на Re: Pasword expiration warning  (Japin Li <japinli@hotmail.com>)
Список pgsql-hackers
Le 07/01/2026 à 06:12, Japin Li a écrit :
Thanks for updating the patch.

1.
$ git apply ~/password_expire_warning-v1.patch
/home/japin/password_expire_warning-v1.patch:71: indent with spaces.        if (MyClientConnectionInfo.warning_message)
/home/japin/password_expire_warning-v1.patch:72: indent with spaces.                ereport(WARNING, (errmsg("%s", MyClientConnectionInfo.warning_message)));
warning: 2 lines add whitespace errors.

2.
+{ name => 'password_expire_warning', type => 'int', context => 'PGC_SIGHUP', group => 'CONN_AUTH_AUTH',
+  short_desc => 'Sets the number of days before password expire to emit a warning at client connection. Default is 7 days, 0 means no warning.',
+  flags => 'GUC_UNIT_S',
+  variable => 'password_expire_warning',
+  boot_val => '7',
+  min => '0',
+  max => '30',
+},
+

The GUC_UNIT_S flag specifies that the unit is seconds, meaning the default
value of 7 corresponds to 7 seconds rather than 7 days. For example:
	# ALTER SYSTEM SET password_expire_warning TO 60;	ERROR:  60 s is outside the valid range for parameter "password_expire_warning" (0 s .. 30 s)

3.
I tested the patch and only received an empty WARNING message. After some
analysis, I found that the warning_message buffer is likely freed after
transaction commit.

Here's a new patch that resolves the issues mentioned earlier.

Furthermore, if the remaining time until expiration is less than one day,
should we display it in minutes (or hours) instead of 0 days?


Thanks for the patch review and improvement.

I missed the GUC_UNIT_S c/p but we can use second as unit. I have fixed your patch update because in this case the result variable must not be turned into days but kept in seconds to be compared to the GUC value.

I have also added the missing GUC in the sample configuration file.

I'm not in favor of a high granularity in time display, number of days for me is enough. I the user have the chance to see the 0 day remaining he knows that he must fix that immediately. But why not, it depends of a consensus.


Thanks.

-- 
Gilles Darold
http://hexaculter.ai/