Re: allow changing autovacuum_max_workers without restarting
В списке pgsql-hackers по дате отправления:
| От | Nathan Bossart |
|---|---|
| Тема | Re: allow changing autovacuum_max_workers without restarting |
| Дата | |
| Msg-id | ZnIpuKIW4RO70XeJ@nathan обсуждение исходный текст |
| Ответ на | Re: allow changing autovacuum_max_workers without restarting (Andres Freund <andres@anarazel.de>) |
| Ответы |
Re: allow changing autovacuum_max_workers without restarting
|
| Список | pgsql-hackers |
On Tue, Jun 18, 2024 at 02:33:31PM -0700, Andres Freund wrote: > Another one: > > Have a general cap of 64, but additionally limit it to something like > max(1, min(WORKER_CAP, max_connections / 4)) > > so that cases like tap tests don't end up allocating vastly more worker slots > than actual connection slots. That's a clever idea. My only concern would be that we are tethering two parameters that aren't super closely related, but I'm unsure whether it would cause any problems in practice. -- nathan
В списке pgsql-hackers по дате отправления:
Сайт использует файлы cookie для корректной работы и повышения удобства. Нажимая кнопку «Принять» или продолжая пользоваться сайтом, вы соглашаетесь на их использование в соответствии с Политикой в отношении обработки cookie ООО «ППГ», в том числе на передачу данных из файлов cookie сторонним статистическим и рекламным службам. Вы можете управлять настройками cookie через параметры вашего браузера