От Bertrand Drouvot
Тема Re: Synchronizing slots from primary to standby
Дата
Msg-id Zc5He6laSZ/hAxB0@ip-10-97-1-34.eu-west-3.compute.internal
обсуждение исходный текст
Ответ на Re: Synchronizing slots from primary to standby  (Amit Kapila <amit.kapila16@gmail.com>)
Ответы Re: Synchronizing slots from primary to standby
Список pgsql-hackers
Hi,

On Thu, Feb 15, 2024 at 06:13:38PM +0530, Amit Kapila wrote:
> On Thu, Feb 15, 2024 at 12:07 PM Zhijie Hou (Fujitsu)
> <houzj.fnst@fujitsu.com> wrote:
> >
> > Since the slotsync function is committed, I rebased remaining patches.
> > And here is the V88 patch set.
> >

Thanks!

> 
> Please find the improvements in some of the comments in v88_0001*
> attached. Kindly include these in next version, if you are okay with
> it.

Looking at v88_0001, random comments:

1 ===

Commit message "Be enabling slot synchronization"

Typo? s:Be/By

2 ===

+        It enables a physical standby to synchronize logical failover slots
+        from the primary server so that logical subscribers are not blocked
+        after failover.

Not sure "not blocked" is the right wording.
"can be resumed from the new primary" maybe? (was discussed in [1])

3 ===

+#define SlotSyncWorkerAllowed()        \
+       (sync_replication_slots && pmState == PM_HOT_STANDBY && \
+        SlotSyncWorkerCanRestart())

Maybe add a comment above the macro explaining the logic?

4 ===

+#include "replication/walreceiver.h"
 #include "replication/slotsync.h"

should be reverse order?

5 ===

+       if (SlotSyncWorker->syncing)
        {
-               SpinLockRelease(&SlotSyncCtx->mutex);
+               SpinLockRelease(&SlotSyncWorker->mutex);
                ereport(ERROR,
                                errcode(ERRCODE_OBJECT_NOT_IN_PREREQUISITE_STATE),
                                errmsg("cannot synchronize replication slots concurrently"));
        }

worth to add a test in 040_standby_failover_slots_sync.pl for it?

6 ===

+static void
+slotsync_reread_config(bool restart)
+{

worth to add test(s) in 040_standby_failover_slots_sync.pl for it?

[1]: https://www.postgresql.org/message-id/CAA4eK1JcBG6TJ3o5iUd4z0BuTbciLV3dK4aKgb7OgrNGoLcfSQ%40mail.gmail.com

Regards,

-- 
Bertrand Drouvot
PostgreSQL Contributors Team
RDS Open Source Databases
Amazon Web Services: https://aws.amazon.com



В списке pgsql-hackers по дате отправления:

Предыдущее
От: Tomas Vondra
Дата:
Сообщение: Re: planner chooses incremental but not the best one
Следующее
От: Bertrand Drouvot
Дата:
Сообщение: Re: Synchronizing slots from primary to standby