On 16 February 2018 06:54:43 CET, Azimuddin Mohammed <azimeiu@gmail.com> wrote:
>Hello All,
>I am getting below Warning messages in logs after starting postgres,
>can
>some please help me here
>
>LOG: could not bind socket for statistics collector: Cannot assign
>requested address
>
>LOG: disabling statistics collector for lack of working socket
>
>WARNING: autovacuum not started because of misconfiguration
>
>HINT : Enable the "track_counts" option.
>
>MultiXact member wraparound protections are now enabled
>
>
>I tried enabling track_counts but it did not help.
>
>
>Any guidance is much appreciated here.
>
>
>Thanks in Advance!


Which operating system? Please disable all firewalls and try it again.