Fix autovacuum launcher shutdown sequence
It was previously possible to have the launcher re-execute its main loop
before shutting down if some other signal was received or an error
occurred after getting SIGTERM, as reported by Qingqing Zhou.
While investigating, Tom Lane further noticed that if autovacuum had
been disabled in the config file, it would misbehave by trying to start
a new worker instead of bailing out immediately -- it would consider
itself as invoked in emergency mode.
Fix both problems by checking the shutdown flag in a few more places.
These problems have existed since autovacuum was introduced, so
backpatch all the way back.
Branch
------
REL9_2_STABLE
Details
-------
http://git.postgresql.org/pg/commitdiff/37dc228e8d3de65895ef8b41c0c4a40b2983e32b
Modified Files
--------------
src/backend/postmaster/autovacuum.c | 16 +++++++++++++---