The following bug has been logged on the website:
Bug reference: 6386
Logged by: Max Kunz
Email address: max.kunz@atip.de
PostgreSQL version: 9.0.0
Operating system: CentOs
Description:=20=20=20=20=20=20=20=20
Hello,
i've got a Problem during PITR.
The Systems stops always with fatal error:
FATAL: requested recovery stop point is before consistent recovery point.
One system is configured as standby, performing stream and WAL replication.
Another system is running in primary mode.
I have verified that the standby system performed the basebackup
successfully. Hours later I did like to perform a PITR. I use a target_time
which is one hour later than stop_basebackup_time. In spite of that fact,
i've got the error message.
I'm able to start this server in primary mode, but it's not possible to
perform a PITR one minute ago.
Do you have any idea why the system don't find a consistent point for PITR
but for normal startup in primary mode?
kind regards Max