Re: Fix slot synchronization with two_phase decoding enabled
От | Dilip Kumar |
---|---|
Тема | Re: Fix slot synchronization with two_phase decoding enabled |
Дата | |
Msg-id | CAFiTN-vxo1Wz_ipwZ3R+Fm3DsVkXgBp-vMJCJp3w+0S_pm6C1A@mail.gmail.com обсуждение исходный текст |
Ответ на | Fix slot synchronization with two_phase decoding enabled ("Zhijie Hou (Fujitsu)" <houzj.fnst@fujitsu.com>) |
Ответы |
Re: Fix slot synchronization with two_phase decoding enabled
Re: Fix slot synchronization with two_phase decoding enabled |
Список | pgsql-hackers |
On Tue, Jun 3, 2025 at 11:05 AM Nisha Moond <nisha.moond412@gmail.com> wrote: > > > Attached v17 patches. Added a top-up patch 0002 implementing the idea > suggested by Amit above. I have started reviewing this, although I haven't done a complete review yet, but I have a question on the fix we are trying to do, IIUC we are disallowing to use 'two phase' and 'failover' options together at the create slot time and now users has to create slot with one of the option and later enable other option right (if user want to use both options)? But don't you think it will affect usability? because if a user wants to use both the options together then after creating the slot they need to track when is the right time to enable the other option? Not sure if anyone else has this concern or it's just me? -- Regards, Dilip Kumar Google
В списке pgsql-hackers по дате отправления: