Re: RAID 1 - drive failed - very slow queries even after drive replaced
В списке pgsql-general по дате отправления:
| От | tv@fuzzy.cz |
|---|---|
| Тема | Re: RAID 1 - drive failed - very slow queries even after drive replaced |
| Дата | |
| Msg-id | 78c68456526930bd70d2c8a63c873fa6.squirrel@sq.gransy.com обсуждение |
| Ответ на | RAID 1 - drive failed - very slow queries even after drive replaced (Merrick <merrick@gmail.com>) |
| Список | pgsql-general |
> Hi, > > I am looking for some advice on where to troubleshoot after 1 drive in > a RAID 1 failed. > > Thank you. > > I am running v 7.41, I am currently importing the data to another > physical server running 8.4 and will test with that once I can. In the > meantime here is relevant info: > > Backups used to take 25 minutes, and now take 110 minutes, before > replacing the drive it became clear the backup was not going to finish > since in 120 minutes it had only finished 200mb of 2.8gb. What kind of RAID is this? I know it's RAID1, but is it built using linux sw raid (md), or is it some other solution (like a hw card)? Can you post some diagnostics info like mdadm --detail /dev/md1 or something like that? I guess this would be reflected in the iostat output (at least for the 'md') but I'm not sure. Maybe there's something still in progress (sync of the new drive?). Tomas
В списке pgsql-general по дате отправления:
Сайт использует файлы cookie для корректной работы и повышения удобства. Нажимая кнопку «Принять» или продолжая пользоваться сайтом, вы соглашаетесь на их использование в соответствии с Политикой в отношении обработки cookie ООО «ППГ», в том числе на передачу данных из файлов cookie сторонним статистическим и рекламным службам. Вы можете управлять настройками cookie через параметры вашего браузера