Re: [NOVICE] Strange problem with autovacuum

Поиск
Список
Период
Сортировка
От Efraín Déctor
Тема Re: [NOVICE] Strange problem with autovacuum
Дата
Msg-id 447a2f76-1f0d-2bf8-58d2-65e1982087d0@motumweb.com
обсуждение исходный текст
Ответ на Re: [NOVICE] Strange problem with autovacuum  (Stephen Froehlich <s.froehlich@cablelabs.com>)
Список pgsql-novice

Hello.

Checkpoint settings:

checkpoint_segments = 128              
checkpoint_timeout = 1h 

It doesnt seem that the workers are being cancelled (I do not have any indication of this on the logs).

Thanks

El 14/11/2017 a las 10:15 a. m., Stephen Froehlich escribió:

What are your checkpoint / wal settings?

 

Are there any log entries at those times about autovacuums being cancelled?  The log will typically give a reason.

 

--Stephen

 

From: pgsql-novice-owner@postgresql.org [mailto:pgsql-novice-owner@postgresql.org] On Behalf Of Efraín Déctor
Sent: Tuesday, November 14, 2017 8:46 AM
To: pgsql-novice@postgresql.org
Subject: [NOVICE] Strange problem with autovacuum

 

CableLabs WARNING: The sender of this email could not be validated and may not match the person in the "From" field.

Hello list.

I have a strange problem with one of our servers (PostgreSQl 9.2.8). Every monday the autovacuum workers seems to stop working (the workers decrease in number) this causes that 5 tables that are constantly updated and deleted to be really slow.

I have this settings on postgresql.conf:

maintenance_work_mem = 7936MB
autovacuum = on
#log_autovacuum_min_duration = -1
autovacuum_max_workers = 12
#autovacuum_naptime = 1min
#autovacuum_vacuum_threshold = 50
#autovacuum_analyze_threshold = 50
#autovacuum_vacuum_scale_factor = 0.2
#autovacuum_analyze_scale_factor = 0.1
#autovacuum_freeze_max_age = 200000000
#autovacuum_vacuum_cost_delay = 20ms
#autovacuum_vacuum_cost_limit = -1

Per table I have this settings:

datosr

  autovacuum_enabled=true,
  autovacuum_vacuum_threshold=50,
  autovacuum_vacuum_scale_factor=0.1,
  autovacuum_vacuum_cost_limit=1000

datose

  autovacuum_enabled=true,
  autovacuum_vacuum_threshold=50,
  autovacuum_vacuum_scale_factor=0.1,
  autovacuum_vacuum_cost_limit=1000

idig_h

  autovacuum_enabled=true,
  autovacuum_vacuum_threshold=1000,
  autovacuum_vacuum_cost_limit=2000

iodig

 autovacuum_enabled=true,
  autovacuum_vacuum_threshold=1000,
  autovacuum_vacuum_cost_limit=2000

ia
  autovacuum_vacuum_threshold=50,
  autovacuum_vacuum_scale_factor=.1,
  autovacuum_vacuum_cost_limit=1000

I bases those settings by reading this blog entry: https://blog.2ndquadrant.com/autovacuum-tuning-basics/

It seems that I am doing something wrong, could you guys please point me in the right direction?

 

Thank you very much


В списке pgsql-novice по дате отправления:

Предыдущее
От: Stephen Froehlich
Дата:
Сообщение: Re: [NOVICE] Strange problem with autovacuum
Следующее
От: "David G. Johnston"
Дата:
Сообщение: Re: [NOVICE] Strange problem with autovacuum