Hi,
Am Freitag, den 15.03.2019, 11:50 +0900 schrieb Michael Paquier:
> On Thu, Mar 14, 2019 at 04:26:20PM +0100, Michael Banck wrote:
> > Am Donnerstag, den 14.03.2019, 15:26 +0100 schrieb Magnus Hagander:
> > > One big-hammer method could be similar to what pg_upgrade does --
> > > temporarily rename away the controlfile so postgresql can't start, and
> > > when done, put it back.
> >
> > That sounds like a good solution to me. I've made PoC patch for that,
> > see attached.
>
> Indeed. I did not know this trick from pg_upgrade. We could just use
> the same.
>
> > The only question is whether pg_checksums should try to move pg_control
> > back (i) on failure (ii) when interrupted?
>
> Yes, we should have a callback on SIGINT and SIGTERM here which just
> moves back in place the control file if the temporary one exists. I
> have been able to grab some time to incorporate the feedback gathered
> on this thread, and please find attached a new version of the patch to
> add --enable/--disable.
Thanks!
One thing stood out to me while quickly looking over it:
+ /*
+ * Flush the control file and its parent path to make the change
+ * durable.
+ */
+ if (fsync_fname(controlfile_path, false, progname) != 0 ||
+ fsync_parent_path(controlfile_path, progname) != 0)
+ {
+ /* errors are already logged on failure */
+ exit(1);
+ }
ISTM this would not run fsync_parent_path() unless the first fsync fails
which is not the intended use. I guess we need two ifs here?
Michael
--
Michael Banck
Projektleiter / Senior Berater
Tel.: +49 2166 9901-171
Fax: +49 2166 9901-100
Email: michael.banck@credativ.de
credativ GmbH, HRB Mönchengladbach 12080
USt-ID-Nummer: DE204566209
Trompeterallee 108, 41189 Mönchengladbach
Geschäftsführung: Dr. Michael Meskes, Jörg Folz, Sascha Heuer
Unser Umgang mit personenbezogenen Daten unterliegt
folgenden Bestimmungen: https://www.credativ.de/datenschutz