Greg Stark <stark@mit.edu> writes:
> Hm. I seem to have picked a bad checkout. I took the last one before
> the revert (45aa88fe1d4028ea50ba7d26d390223b6ef78acc).
FWIW, I think that's the first one *after* the revert.
> 2021-12-17 17:51:51.688 EST [50955] LOG: background worker "parallel
> worker" (PID 54073) was terminated by signal 10: Bus error
I'm betting on weird emulation issue. None of my real PPC machines
showed such things.
regards, tom lane