On Friday, January 12, 2024 8:00 PM Masahiko Sawada <sawada.mshk@gmail.com> wrote:

Hi,

> 
> On Thu, Jan 11, 2024 at 7:53 PM Amit Kapila <amit.kapila16@gmail.com> wrote:
> >
> > On Tue, Jan 9, 2024 at 6:39 PM Amit Kapila <amit.kapila16@gmail.com> wrote:
> > >
> > > +static bool
> > > +synchronize_one_slot(WalReceiverConn *wrconn, RemoteSlot
> > > +*remote_slot)
> > > {
> > > ...
> > > + /* Slot ready for sync, so sync it. */ else {
> > > + /*
> > > + * Sanity check: With hot_standby_feedback enabled and
> > > + * invalidations handled appropriately as above, this should never
> > > + * happen.
> > > + */
> > > + if (remote_slot->restart_lsn < slot->data.restart_lsn) elog(ERROR,
> > > + "cannot synchronize local slot \"%s\" LSN(%X/%X)"
> > > + " to remote slot's LSN(%X/%X) as synchronization"
> > > + " would move it backwards", remote_slot->name,
> > > + LSN_FORMAT_ARGS(slot->data.restart_lsn),
> > > + LSN_FORMAT_ARGS(remote_slot->restart_lsn));
> > > ...
> > > }
> > >
> > > I was thinking about the above code in the patch and as far as I can
> > > think this can only occur if the same name slot is re-created with
> > > prior restart_lsn after the existing slot is dropped. Normally, the
> > > newly created slot (with the same name) will have higher restart_lsn
> > > but one can mimic it by copying some older slot by using
> > > pg_copy_logical_replication_slot().
> > >
> > > I don't think as mentioned in comments even if hot_standby_feedback
> > > is temporarily set to off, the above shouldn't happen. It can only
> > > lead to invalidated slots on standby.
> > >
> > > To close the above race, I could think of the following ways:
> > > 1. Drop and re-create the slot.
> > > 2. Emit LOG/WARNING in this case and once remote_slot's LSN moves
> > > ahead of local_slot's LSN then we can update it; but as mentioned in
> > > your previous comment, we need to update all other fields as well.
> > > If we follow this then we probably need to have a check for
> > > catalog_xmin as well.
> > >
> >
> > The second point as mentioned is slightly misleading, so let me try to
> > rephrase it once again: Emit LOG/WARNING in this case and once
> > remote_slot's LSN moves ahead of local_slot's LSN then we can update
> > it; additionally, we need to update all other fields like two_phase as
> > well. If we follow this then we probably need to have a check for
> > catalog_xmin as well along remote_slot's restart_lsn.
> >
> > > Now, related to this the other case which needs some handling is
> > > what if the remote_slot's restart_lsn is greater than local_slot's
> > > restart_lsn but it is a re-created slot with the same name. In that
> > > case, I think the other properties like 'two_phase', 'plugin' could
> > > be different. So, is simply copying those sufficient or do we need
> > > to do something else as well?
> > >
> >
> > Bertrand, Dilip, Sawada-San, and others, please share your opinion on
> > this problem as I think it is important to handle this race condition.
> 
> Is there any good use case of copying a failover slot in the first place? If it's not
> a normal use case and we can probably live without it, why not always disable
> failover during the copy? FYI we always disable two_phase on copied slots. It
> seems to me that copying a failover slot could lead to problems, as long as we
> synchronize slots based on their names. IIUC without the copy, this pass should
> never happen.

Thanks for the suggestion. I also don't have a use case for this.
Attach the V61 patch set that addresses this suggestion. And here is the
summary of the changes made in each patch.

V61-0001
1. Reverts the changes in copy_replication_slot.

V61-0002

1. Adds the documents for the steps that user needs to follow to ensure the
   standby is ready for failover
2. Directly update the fields restart_lsn/confirmed_flush/catalog_xmin instead
   of using APIs like LogicalConfirmReceivedLocation
3. Updates all the fields(two_phase, failover, plugin) when syncing the slots
4. fixes CFbot failures.
5. Some code style adjustment. (pending comments in last version)
6. Remove some unnecessary Assert and variable assignment (off-list comments from Peter)

Thanks Shveta for working on 4 and 5.

V61-0003
1. Some documents update related to standby_slot_names and the steps for
   failover.

V61-0004
- No change.

Best Regards,
Hou zj