Re: Hot standby, recent changes

Поиск
Список
Период
Сортировка
От Heikki Linnakangas
Тема Re: Hot standby, recent changes
Дата
Msg-id 4B1BF8AF.9000704@enterprisedb.com
обсуждение исходный текст
Ответ на Re: Hot standby, recent changes  (Simon Riggs <simon@2ndQuadrant.com>)
Ответы Re: Hot standby, recent changes  (Simon Riggs <simon@2ndQuadrant.com>)
Список pgsql-hackers
Simon Riggs wrote:
> On Sun, 2009-12-06 at 12:32 +0200, Heikki Linnakangas wrote:
>> 4. Need to handle the case where master is started up with
>> wal_standby_info=true, shut down, and restarted with
>> wal_standby_info=false, while the standby server runs continuously. And
>> the code in StartupXLog() to initialize recovery snapshot from a
>> shutdown checkpoint needs to check that too.
> 
> I don't really understand the use case for shutting down the server and
> then using it as a HS base backup. Why would anyone do that? Why would
> they have their server down for potentially hours, when they can take
> the backup while the server is up? If the server is idle, it can be
> up-and-idle just as easily as down-and-idle, in which case we wouldn't
> need to support this at all. Adding yards of code for this capability
> isn't important to me. I'd rather strip the whole lot out than keep
> fiddling with a low priority area. Please justify this as a real world
> solution before we continue trying to support it.

This affects using a shutdown checkpoint as a recovery start point
(restore point) in general, not just a fresh backup taken from a shut
down database.

Consider this scenario:

0. You have a master and a standby configured properly, and up and running.
1. You shut down master for some reason.
2. You restart standby. For some reason. Maybe by accident, or you want
to upgrade minor version or whatever.
3. Standby won't accept connections until the master is started too.
Admin says "WTF?"

--  Heikki Linnakangas EnterpriseDB   http://www.enterprisedb.com