Re: RAID 1 - drive failed - very slow queries even after drive replaced

Поиск
Список
Период
Сортировка
От Andrew Sullivan
Тема Re: RAID 1 - drive failed - very slow queries even after drive replaced
Дата
Msg-id 20110323191732.GS45735@shinkuro.com
обсуждение исходный текст
Ответ на Re: RAID 1 - drive failed - very slow queries even after drive replaced  (Alban Hertroys <dalroi@solfertje.student.utwente.nl>)
Список pgsql-general
On Wed, Mar 23, 2011 at 08:08:47PM +0100, Alban Hertroys wrote:
> er or motherboard? Maybe the new drive has different requirements than the old one had (more power, for example)?

Or a newer but backward-plug-compatible interface?  Often, the new
drive in the old plug only uses the Right Features once its
compatibility mode has been turned off.  (This is at least true in my
experience.  Not saying it's the cause of the present issue, though.)

A

--
Andrew Sullivan
ajs@crankycanuck.ca